Languages

Fixturlaser NXA Geometry

Geometry the easy way

FIXTURLASER NXA GEOMETRY

The Fixturlaser NXA Geometry includes the following software:

STANDARD EQUIPMENT

The Fixturlaser NXA Geometry comes in two versions, the Fixturlaser NXA Geometry Basic and Fixturlaser NXA Geometry Full respectively. The content is the same with one exception for the Fixturlaser NXA Geometry Full version, which also includes an extra RS sensor unit, as described below.

 

RS SENSOR UNIT

An extra RS sensor unit that can be used as reference detector during your measurement.

 

RS sensor unit

The extra RS sensor unit is an additional stationary reference receiver during the measurement, which you zero at the start of the measurement process. You are then able to control, at any time during the measurement, that the transmitter has not been moved during the actual measurement, which would otherwise cause incorrect measurement values.

 

OPTIONAL EQUIPMENT

 

TRANSMITTERS

In order to perform straightness and flatness measurements, you also need to choose between the four different laser transmitters listed below.

 

For straightness measurements, choose between the T110 or T111:

 

Laser transmitter T110

Battery powered laser transmitter with built-in micrometer screws for adjustment of the laser beam in horizontal and vertical level.

 
 

Laser transmitter T111

Laser transmitter with built-in micrometer screws for adjustment of the laser beam in horizontal and vertical level. The T111 is powered by the supplied AC-adapter (110/230 Volts).

 

For straightness and flatness measurements, choose between the T21 or the T220:

 

Laser transmitter T21

The 21 laser transmitter is battery powered. The laser transmitter has a built-in angular prism in a turret allowing the creation of a 360° laser plane. Laser beam levelling can be made in relation to the horizontal plane. The turret can easily be detached giving a laser beam perpendicular to the X-Y plane.

 

Laser transmitter T220

Battery powered laser transmitter of diode type with built-in spirit levels and an angular prism. It is equipped with micrometer screws for adjustment of the laser beam in horizontal and vertical level. The optical head can be rotated 360° in order to project a reference plane with the laser beam.

 

What's in the case?

FIXTURLASER NXA GEOMETRY BASIC
1 Fixturlaser NXA display unit
1 Fixturlaser RM sensor unit
1 Fixturlaser BT2 wireless unit
1 rotating magetic base
1 tape measure 5 m
1 power supply complete NXA
2 angled universal tools
3 pcs of battery LR6 1.5V (AA)
1 USB memory stick
1 Fixturlaser NXA Manual in English 
1 Fixturlaser NXA Manual CD multi-language
1 Fixturlaser NXA Geometry Manual in English
1 Fixturlaser NXA Geometry Manual CD multi-language
 
FIXTURLASER NXA GEOMETRY FULL
All of the above articles
1 RS sensor unit

Technical specification

Fixturlaser NXA Geometry

 
Fixturlaser RM/RS Sensor unit  
Weight 116 g (4.09 oz) 
Dimensions (with cable attached) 57 mm x 50 mm x 40 mm (2.2 in x 2.0 in x 1.6 in)
Detector size 20 mm x 20 mm (0.8 in x 0,8 in)
Measurement accuracy 1% ± 3 µm
   
BT2 Wireless unit  
Weight 190 g (6.7 oz) with batteries
Dimensions 82 mm x 50 mm x 40 mm (3.2 in x 2.0 in x 1.6 in)
Wireless communication Class II Bluetooth transmitter
Communication range 10 m (33 ft)
Power supply 3 AA (LR6) batteries
Operating time 10 hours continuously
   
T110 Transmitter  
Operating temperature 0 to 50°C (32 to 122°F)
Storage temperature -20 to 70°C (-4 to 158°F)
Weight 1100 g (2.43 lbs)
Laser 650 nm class II diode laser
Dimensions 60 mm x 60 mm x 140 mm (2.4 in x 2.4 in x 5.5 in)
Measurement distance Up to 50 m (164 ft)
Power supply 2 batteries type LR6 (AA)
Operating time 15 hours 
   
T111 Transmitter  
Operating temperature 0 to 50°C (32 to 122°F)
Storage temperature -20 to 70°C (-4 to 158°F)
Weight 1030 g (2.27 lbs)
Dimensions 60 mm x 60 mm x 140 mm (2.4 in x 2.4 in x 5.5 in)
Laser 650 nm class II diode laser
Measurement distance Up to 50 m (164 ft)
Power supply AC-adapter 110/230 Volts
   
T21 Transmitter  
Operating temperature 0 to 50°C (32 to 122°F)
Storage temperature -20 to 70°C (-4 to 158°F)
Weight 1150 g (2.54 oz)
Dimensions 100 mm x 103 mm x 109 mm (3.9 in x 4.0 in x 4.2 in)
Laser 650 nm class II diode laser
Measurement distance Up to 20 m (66 ft)
Laser sweep flatness ±0.02 mm/m
Angular prism accuracy ±0.02 mm/m
Power supply 2 batteries type LR6 (AA)
Operating time 15 hours
   
T220 Transmitter  
Operating temperature 0 to 50°C (32 to 122°F)
Storage temperature -20 to 70°C (-4 to 158°F)
Weight 3500 g (7.72 lbs)
Dimensions 175 mm x 175 mm x 115 mm (6.9 in x 6.9 in x 4.5 in)
Laser 650 nm class II diode laser
Measurement distance Up to 50 m (164 ft)
Laser sweep flatness ±0.02 mm/m
Angular prism accuracy ±0.02 mm/m
Power supply 4 batteries type LR6 (AA)
Operating time 15 hours

Accessories

 XY table with Fixturlaser NXA Geometry    
XY table XY table with long arms

3 long arms with magnets for XY table, ø300 - 600 mm

     
Set of short arms for XY table, ø180 - 300 mm Long arms 800 mm for transmitter fixture Receiver holder cc80 mm
 Fixturlaser Magnetic base    
Magnetic base Angular bracket with tripod adapter

Target for RM and RS sensors